美国WA电极M10
Model 10 General Purpose pH Sensor
Features
. Select pH or ORP Measurement
. Temperature Compensation Pt100 or Pt1000
. Non-fouling porous Teflon® Liquid Junction
. Large Volume Reference Electrolyte Reservoir
. Compact Design
. 1/2" MNPT Process Connections
. Designed for Flow Through and Submersion Applications
. Suitable for High Temperature Use
Applications
. Potable Water
. Cooling Towers
. Surface Water Monitoring
. Fresh and Salt Water Aquariums
. Fish Farming
. Hydroponics
Description
Model 10 pH Sensor is designed for use in general purpose water applications. The large volume single junction reference cell coupled with the non-fouling porous Teflon® liquid junction assures a long life in general service.
Specifications
Body Material | Ryton® |
O-Rings | Viton® |
Measuring Range | 0 to 14 pH |
Temperature Range | -5 to 80oC (23 to 176oF) Standard Version 25 to 110oC (77 to 230oF) High Temp Version |
Pressure Range | 0 to 6.9 bar (0 to 100 psig) |
Drift | < 2.0 mV/week |
Response Time @ 25oC (77oF) | 95% of reading in 10 seconds |
pH Glass Bulb Impedance @ 25oC (77oF) | 80 Megohms (Standard Version) 150 Megohms (High Temp Version) |
1 United States Patent No. 4,128,468
® Teflon and Viton are Registered Trademarks of E.I. Dupont de Nemours Company
® Ryton is a registered trademark of Philips 66 Co.
REGISTERED TO ISO 9001 CERTIFICATE NO. 00-1011
Amer in USA
4745 East Bryson Street Anaheim, CA 92807-1901
Model 10 General Purpose pH Sensor
Ordering Information
Model 10 | Description |
M-10 | General Purpose pH Sensor with Protective Guard Single Junction Reference Cell No Temperature Compensation Process Connections ½” MNPT Insertion Length 16.5mm (0.65”) 3.3m (10 ft.) Cable with BNC |
Measurement Options | Description |
ORP | Platinum ORP Electrode |
HT | For continuous high temperature use >80oC (176oF) |
Temperature Compensation | Description |
PT100 | Temperature Compensation, 100 Ohm RTD |
PT1000 | Temperature Compensation, 1000 Ohm RTD |
3KTC | Temperature Compensation, 3000 Ohm Thermister |
M-10-PT100 | Example Order Number |
Flow Installation
• ½” NPT Pipe Tee (By Others)
• Use Teflon® Tape on Sensor to permit removal for
routine maintenace
• Install shut off valves upstream and downstream of sensor
• Optimum flow rate is 3 to 5 GPM
• Sensor must remain in solution at all times
Note: Variations in design of plastic plumbing parts from different
manufactures can be expected. Check tolerances prior to installation.
Amer in USA